DETAILS:
- Low cost, Goodman replacement board
- Microprocessor-based precision
- Controls inducer and blower fan motors, hot surface igniter, and gas valve
- Monitors timing, trial for ignition, flame sensing, pressure switches, limit switches
- Designed for 100% gas shutoff in case of ignition failure
- Reverse polarity protection
- Compatible with 24 VAC standard thermostat
- Twinning compatible with another ICM2810 control board
- Compatible with LP or natural gas
- Provides diagnostic LED to aid in testing/troubleshooting
- Pre-purge Time: 15 seconds
- Igniter Warm Up Time: 18 seconds
- Post-Purge Time: 15 seconds
- Total Trials for Ignition: 3 (auto rest after 1 hour)
- Heat Blower On: 30 seconds
- Heat Blower Off: Selectable 90/120/150/180 seconds
- Fan (Heat) On/Off Delay: 1 second
- Cool On: 5 seconds
- Cool Off: 45 seconds